Battery

PEOPLESOFT ODBC DRIVERS FOR MAC

June 23, 2018

In the case of query objects, the transaction is automatically closed upon termination of the statement handle. SQLDriverConnect handles the entire connection process for an application, prompting the end user for any information to complete the connection. SQLNumResultCols can be called successfully only when the statement handle is in the prepared or executed state. The settings in the grid are not saved until you click Apply or OK. Although this tab is specifically for developer settings, all of the PeopleSoft Configuration Manager settings may affect developers, especially the Startup tab and the Process Scheduler tab for the default profile. Enter the IP address or the resolvable server name of the application server you specified in the Application Server Name field. Each workstation must have a default profile, which is used when the user signs in to a database or application server that isn’t listed in any profile.

Uploader: Gardalmaran
Date Added: 17 February 2009
File Size: 11.68 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 79150
Price: Free* [*Free Regsitration Required]

For example, there may be one database for tracking financial information, peoplesoft odbc as expense reports, and another database for human resources processes, such as benefits enrollment. Use the Connect Password field to define a default connect ID password.

Understanding How to Run Client Setup

In this model, the SQL statement is prepared sent to the server, parsed, and optimized first and executed later. Select this option if you need to run “dirty read” queries, through PeopleSoft Query during a two-tier peoplesoft odbc. SQLDriverConnect handles the entire connection process for an application, prompting the end user for any information to complete the connection.

As before, such clients can connect to the PeopleSoft database directly using client connectivity software a two-tier connectionor through a PeopleSoft application server a three-tier connection. Peoplesoft odbc ensures that the exported configuration file reflects the current settings.

Adds a shortcut to a standalone peoplesoft odbc that converts RPT files from the format PeopleSoft used in previous peoplesoft odbc to the PeopleTools 8 format.

Before you enter a database or application server on this tab, you should have already installed and configured peoplesoft odbc as documented in the PeopleSoft peoplesoft odbc documentation for your database platform. ODBC supports three connection functions: The connection environment is affected by the workstation settings for PeopleSoft ;eoplesoft Scheduler.

The navigator appears on the first instance of PeopleSoft only. Database type of login can be any of the following values: Closes PeopleSoft Configuration Manager without saving any peoplesoft odbc that you have made.

The default setting is US English. In the Language drop-down list box, specify which peoplesoft odbc you want to display on your PeopleSoft pages.

Understanding How to Run Client Setup

A two-tier connection is required if any of the following is peoplesoft odbc. Applications should allocate at least bytes for this buffer. After a statement is prepared, the application uses hstmt to refer to the statement in later function calls. Select one of the following values:. Selecting the Numeric keypad check box overrides this default behavior for the Enter key on the numeric keypad; instead of selecting the action peoplesoft odbc, pressing the Enter key moves the cursor to the next field in peoplesoft odbc dialog box.

This setting can be used to check whether nVision peoplesoft odbc successfully launched and is able peoplesoft odbc connect to Excel and process the request. This is called after SQLDisconnect. The error state and error text is retrieved from the driver with the SQLError function. If the information in the ODBC. Each query object that runs in ODBC creates a transaction.

Using PeopleSoft Configuration Manager

Access to all supported PeopleSoft databases. XLT peoplesoft odbc, which defines the Microsoft Excel styles used to format output. This diagram illustrates the components involved in PeopleSoft Open Query architecture. Connects to a PeopleSoft database, prompting the user for any login parameters not provided peoplesoft odbc the caller. Pointer to the total number of bytes returned in szConnStrOut.

The result set returned is for the current user ID. If an application peoplesoft odbc SQLDisconnect before it has freed all statement handles that are associated with the peoplesoft odbc, the driver frees those statement handles after it successfully disconnects from the data source.

This function assumes that a connection may be completed by supplying only a DSN, peoplesoft odbc, and password. For Informix, enter the server name in lowercase. ODBC-enabled applications use these functions to dynamically query the driver for information about the result set and the input and output values.